    1. hydrotechnik

      Turbine volume flow sensor with increased IP protection
      hydrotechnik in china
      Turbine volume flow sensor RE4 data download
      hydrotechnik flow sensor advantages at a glance
      • Ideally suited for use with mineral oil and HFA-/HFC-liquids,skydrol, water etc.
      • Integrated test points for acquiring pressure and temperature measurements
      • Small physical dimensions, high pressure capability
      • Installation in any position, reverse flow operation
      • Low operational noise, high level of reproducibility
      • Improved accuracy through linearization feature with the corresponding evaluative instrumentation from within our product range
      • Measuring range expandable through linearization feature

      Hydrotechnik flow sensor qualities

      Measuring principle volume fl ow
      Viscosity range 1-270mm²/s (cSt)
      Medium temperature max. +120 °C
      Environmental temperature -20 ... +85 °C
      Storage temperature -20 ... +85 °C
      Output signal frequency (rectangle) / 4 ... 20 mA
      Supply voltage Ub 12 ... 24 VDC
      Electrical measuring connector device connector 3 pole AMP, acc. to DIN 72585
      Protection type (EN 60529 / IEC 529) IP 69
      Tightening torque 10 Nm (± 2 Nm)
      Calibration viscosity 30 mm²/s (cSt)
      Material turbine casing Aluminium AlZnMgCu 1,5
      Material turbine wheel 1.4122 (for measuring range 1.0 ... 10 l/min)
      1.0718 (for all other measuring ranges)
      Material sealings FKM
      Material sensor casing 1.4301
      Suitable measuring cable customer-specific
      measuring range Error limit* L SW G
      l/min   mm    
      1.0 ... 10.0 ± 2.5 120 41 ISO 228-G¼
      7.5 ... 75.0 130 46 ISO 228-G3/4
      15 ... 300 150 55 ISO 228-G1
      25 ... 600 ± 2.0 174 60 ISO 228-G1¼
      Hydrotechnik Turbine volume flow sensor Electrical connections
      Pin assignment 4 ... 20 mA
      Pin 1 = signal +
      Pin 2 = signal – / GND
      Pin 3 = + Ub
      Hydrotechnik Turbine volume flow sensor Orders
      Measuring
      range
      Allowed working
      pressure
      Viscosity
      range
      Error limit* Order number / weight
      l/min bar MPa mm²/s (cSt)   frequency weight (g)
      1.0...10.0 (RE4-10) 420 42 1 ... 60 ± 2.5 %

      31N7-01-35.030

      681
      7.5...75.0 (RE4-75) 1 ... 100 ± 2.5 % 31N7-70-35.030 869
      15...300 (RE4-300) 1 ... 100 ± 2.5 % 31N7-71-35.030
      1,206
      25...600 (RE4-600) 350 35 1 ... 100 ± 2.0 % 31N7-72-35.030 1,498